AHP-55 / AHP-55 Series (Instructions)

AHP-55 Instructions

Installation:
Fill vessel at a rate of 1 to 2 gallons per minute through the outlet port to force trapped air out inlet of vessel. Allow vessel to stand 24 hours with inlet port open to permit de-gassing of carbon bed. Add additional water to completely fill vessel before placing in service. During initial startup, recycle water to remove carbon fines. Do this until water runs clear.

Operation: The granular activated carbon in this vessel will adsorb impurities from the water flow. Removal efficiency is reduced as flow rates are increased. The recommended maximum flow rate is 10 gallons per minute, however some impurities may require less flow to increase carbon contact time. As the carbon becomes saturated, some impurities will begin to pass through. To extend the useful life of the vessel it is recommended that two vessels be plumbed in series. Replace the first vessel when influent and effluent concentrations in the first vessel are equal. Move the second vessel to the first position and place the new vessel last.

Pressure relief valve: Lift the pressure release valve from time to time to release any built up gasses. The relief port should be plumbed into an upstream source to prevent uncontrolled discharge of impure liquid should pressures exceed 30 psig.

Drain Vessel: (Method 1): Using a shop vacuum, hold vacuum hose tight to 2" discharge opening and draw out water. (Method 2): Remove 2" bung from bottom of drum and slice 2 or 3 clean cuts through both liners with a sharp knife. Avoid punching holes in liners. Several clean slices will allow water to seep out but retain the carbon granules. Allow to drain 24 hours before shipping.

Caution: 1) Do not exceed 30 psig operating pressure. All air must be purged from vessel to prevent storage of energy from the compression of gas 2) Activated carbon has been known to react adversely with some contaminants. Test carbon before if affects are unknown. 3) Pre-filter for suspended solids should be used to prevent particulate fouling of carbon bed. 4) PH of water may be elevated during startup. Water may require neutralization until effluent meets influent values

Warranty: This product is designed to remove organic impurities from water. Due to the number of hidden variables in water there is no certainty of its capacity. Seller warrants that the product is free from defects such as leaks from seals. Many of the components in this product have been or may have been recycled. Seller will not be liable for loss or damage to property or any incidental or consequential loss or expense from property damage due directly or indirectly from the use of the product.