Ozone / PB30 - PB60 Ozone "Plasma Block™" Generators
Common usage applications/scenarios
- Disinfectant - With a 99.9 percent kill rate, it's far more effective than current sanitizing methods. The Food and Drug Administration recently gave the go-ahead to use it commercially in U.S. supermarkets and food-processing facilities.
- Odor Elimination - Ozone is effective in eliminating odorous organics such as Hydrogen Sulfide (H2O) as well as sulfur, carbon disulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide. Other forms of odor containing nitrogen compounds such as ammonia, trimethylamine, dimethylamine and n-propylamine are also removed.
- Color Removal - requires an ozone dosage which in most cases fluctuates from 50 to 100 mg/l, for color reduction of 85-92%.
- BOD/COD reduction – Used as a pre-treatment application, Ozone can cut down BOD/COD by about 40%, as well as Volatile Fatty Acids (VFD).
Ozone "Plasma Block" Generator technology for pre-treatment systems and biological applications
|
![]() |
PB30-PB60 grams/hr Plasma Block Corona Discharge Technology We offer standard and custom configurations in numerous ozone markets
| SPECIFICATIONS | PB30SI | PB60DI | PB60CS2 |
| System Control | Manual or Dry Contact | Manual or Dry Contact | PLC |
| Number of Generators | One | One | One or Two |
| Ozone Output g/hr3 | 36 g/hr (1.9 lbs./day) | 72 g/hr (3.8 lbs/day) | 36-72 g/hr (3.8 lbs/day) |
| Power Requirements | 120 volt, 10A | 120 volt, 20A | 120 volt, 20A |
| Oxygen Feed Gas | 3 to 10 LPM | 3 to 18 LPM | 3 to 18 LPM |
| UL Enclosure | NEMA 12 Powder Coat | NEMA 12 Powder Coat | NEMA 12 Powder Coat |
| Cooling Water Requirements | Non-Air Cooled | Non-Air Cooled | Non-Air Cooled |
| Pressure Range | 6 to 100 psi | 6 to 100 psi | 6 to 100 psi |
| Dimensions | 26"H x 20"W x 14"D | 26"H x 20.25"W x 13.5"D | 36"H x 30"W x 14"D |
| Weight | 73 lbs. | 180 lbs. | 218 lbs. |
| OPTIONS | PB30SI | PB60DI | PB60CS2 |
| Programmable Logic Control | N/A | N/A | Included |
| Oxygen Feed Gas System | AirSep, Sequal or equal | AirSep, Sequal or equal | AirSep, Sequal or equal |
| Display Configuration Screen | N/A | N/A | Included |
| Remote Monitoring RMT | N/A | N/A | Optional |
| Sensor Display | N/A | N/A | Optional |
| Sensor Signal Control | Optional | Optional | Included |
| Backflow Device | Optional External | Optional External | Optional External |
| Power Supply for Sensors | N/A | N/A | Included |
| Variable 03 1% tp 100% | Optional PDM | Optional PDM | Included |
| Stainless Steel UL Enclosure | Optional | Optional | Optional |
| Custom UL Enclosures | Optional | Optional | Optional |
PB60S2 Two Single Air Cooled Plasma Block up to 72 grams/hr
|
|
PB60CS2 with PLC Plasma Block up to 72 grams/hr
|
Ozone and Water....
PLC Architecture - Our Ozone Systems include the proper software for the Plasma Block™ to operate with the correct configuration depending on the exact requirements of each application. This includes but is not limited to exact ozone output constrol through OPR or DOM, ambient ozone monitoring, interlocked to pumps valves or other equipment. Remote monitoring is available through the customer's Ethernet and if required the internet. Maintenance - Cell designs using glass dielectrics are of particular concern since these tend to be very temperamental requiring great care in the disassembly, cleaning process and reassembly of the unit. Cell failures can lead to the entire unit shutting down until a highly trained technician can troubleshoot the problem. The Plasma Block™ will eliminate all of these concerns. Our cell is maintenance free. The cell will not self destruct if water finds its way into the reactor chamber. The electronics are design to withstand any water entrainment. The only required maintenance is on the filters of the air prep system. The Plasma Block™ has built in safety features which simply shuts the unit down. After the cells are purged the unit can be started up with confidence. No other cell design can make these claims. Should there actually be a cell failure, the time required to remove and replace a cell is about 15 minutes. The achitecture allows for the unit to continue to procuce ozone through any of the remaining cells. Oxygen Feed Gas - The Plasma Block™ is designed to operate on oxygen. Systems using dry air will develop nitric acid which will build up in the cell causing a reduction in ozone output or cell failure. Using oxygen creates the perfect environment for the plasma block cell operation. High ozone cocentrations and effeiciencies with inlet feed gas due points equal to minus 100°F are achieved. Many ozone systems will run on air or oxygen. For peak operation performance and service, only cells using oxygen feed gas have proven over time to be the most reliable. The Plasma Block™ continues to be the best cell design ever conceived. This design is truly changing everything about the use of ozone, ozone generation and the related applications. No System Warm-Up Required - Unlike older systems which may be running continuously to an ozone destruct unit, the Plasma Block™ design can startup and shut down instantly. With the oxygen system in standby mode, the generators are always ready to perform at peak efficiencies. All high voltage is safely contained completely within the plasma block. This eliminates shock hazards and dirt build up which can cause dangerous flash over. Instant Ozone Whdn Needed - Due to the micro gap design, high concentration ozone is always ready to operate at peak performance. Should the system require 100% ozone, the Plasma Block™ architecture will start the plasma on demand and shut down the plasma as the system dectates. Variable Ozone Output Option - Should there be a requirement for varying the ozone output, our design can allow for a linear turn down to 1%. This is very unique in the industry and allows the operator to keep a very precise control on the systems oranic loading requirements. No Glass Tubes - Glass tubes in older systems require special handling and care and are expensive to replace. Operating at high voltages and lower frequency they require a specific warm up period and tend to be somewhat temperamental. Ask anyone who is using this older technology about the maintenance aspect of tube replacemnt and upkeep. No Wet Air Problems - Wet air is a problem with any ozone generating system. To insure that the Plasma Block™ design is always ready to perform at full potential, only oxygen supply systems are incorporated into our design. Because of this, the dry oxygen feed gas enters the plasma chamber and eliminates the potential for creating nitric acid buildup in the cell. Easy Maintenance & Low Cost - The Plasma Block™ cells are maintenance free. Our design allows for easy access to the hardware for immediate replacement of all components. Items are stocked and readily available. Should the plasma block cells need replacement or refurbishment, they are easily removed in a matter of minutes. With our oxygen feed system, replacement of the plasma block should not be a requirement. Cells can last for 10 years. Huge Energy Savings - Micro Channel™ design results in high concentration ozone at 23,000 hertz/3200 volts. Precision machined aluminum block eliminates inefficient hot spots. Only a 2 psi drop with 10 LMP flow. Maximum cell pressure is over 100 psi. As with any cell the most predictable performance occurs with positive pressure domain. Running at full load the cell only uses 250 watts for an air cooled unit. A Plasma Block system with two Plasma Block™ cells and oxygen system will use about the same power as a microwave oven. (~150 watts @ 120 volts). This should produce over 3 pounds or 1365 grams of ozone per day making it the most efficient system on the market. When you calculate the instant on/off feature the energy saving is tremendous. Water cooled cells are also available and supply ozone amounts up to three times more. |
Touch Screen Computer Interface Integrated Into Your System - We have the knowledge and understanding to ask the correct questions related to your process. Interlock features to pumps, valves, ORP and DOM allow for our ozone system to function as one with your equipment. This insures that if a problem should occur the proper alarms are activated which allow the correct measures to be taken. Should your requirements include the ability to access the system from anywhere in the world we can accomodate you with our touch screen computer interface display. The unit was designed and manufactured for the purpose of showing our integration capabilities for custom hardware unique to customer's requirements. This type of architecture allows operators to interface through a touch screen thereby having direct interaction with a specific process or the monitoring and control of several processes. Computer controlled monitoring, start/stop, auto-run, configurations and alarms can keep operators up to date on the operational parameters of their systems. RMT or Remote Monitoring Technology is available with Ethernet or Internet connections. With this feature you can have the option of alarms calling out to a cell phone, email or pager with the ability to monitor in real time all process parameters. |
![]() |